Click here for more information about laboratory operations and procedures

Flecainide

Item Value
Approval req'd? No
Available Stat? No
Test code FLEC
Performed by Quest
Sendout? Yes
Method LC/MS/MS
Collection Instructions Do not use serum separator tube
Container type Red top
Amount to Collect 8 mL blood
Sample type Serum
Preferred volume 4 mL serum
Min. Volume 1.5 mL serum
UCSF Rejection Criteria Collected in Gold top
Processing notes Refrigerate. Order Quest # 36384P.
Units mg/L
Normal range
Therapeutic 0.20-1.00 mg/L
Toxic > 1.00 mg/L
Critical value Quest Priority-1: ≥ 1.0 mg/L
Synonyms Tambocor
Turn around times Test run Tuesday, Thursday, Saturday. Turnaround time: 2-5 days.
LOINC code 3638-4
Last Updated 10/2/2010 11:51:52 AM
Entry Number 389