Click here for more information about laboratory operations and procedures
KIR Genotype – Low Resolution (New Test)
| Item | Value |
|---|---|
| Approval req'd? | No |
| Available Stat? | Yes |
| Test code | ILKIR |
| Test group | KIR Genotyping |
| Performed by | Immunogenetics & Transplantation Laboratory (ITL) |
| Sendout? | Yes |
| Method | Molecular – SSP |
| Collection Instructions | Fill ACD tube completely. Obtain ACD tube from Specimen Receiving. If being collected with other HLA intermediate resolution typing such as HLA-B, HLA-C, HLA-DR, HLA-DQ, etc., 1 tube is sufficient for all tests. Collect additional samples if white blood cell (WBC) count is low (<1,000). Print out and submit an ITL Requisition with the sample. Click here for Form |
| Container type | Yellow top (ACD) |
| Amount to Collect | 8.5 mL blood |
| Sample type | ACD anticoagulated whole blood. |
| Preferred volume | 8.5 mL blood |
| Min. Volume | 1 mL blood |
| UCSF Rejection Criteria | WBC count too low (<1,000). |
| Processing notes | Keep sample at Room Temperature, DO NOT refrigerate or centrifuge. |
| Normal range | |
| Synonyms | KIR Typing, KIR Genotyping |
| Stability | If kept at ambient temperature, can be good for up to 72 hours. |
| Turn around times | Test run Monday – Friday. Expected TAT for routine test is < 11 working days. |
| CPT coding | 81373 |
| Last Updated | 5/15/2013 10:06:05 AM |
| Entry Number | 1431 |
If you have additional questions regarding this test, please call: 415-353-1667